Emergency Stop & Time Relay
SAFEONE DNSR-2R2
The emergency stop relay is configured individually for your application and can be supplied with instantaneous, off-delayed or on-delayed contact outputs.
Depending on the variant, the time delay can also be set directly on the device. For even more flexibility.
Emergency Stop- & Time Relay easy as pie.
The emergency stop relay is configured individually for your application and can be supplied with instantaneous, off-delayed or on-delayed contact outputs. Depending on the variant, the delay can also be set directly on the device. For even more flexibility.
General Data
Degree of contamination | 2 |
Overvoltage category | III |
Current consumption at 24V | 40mA in rest position 70mA in active position |
Protection (Casing and Terminals) | IP20 |
Protection (Installation Site) | min. IP 54 |
Power consumption at A1/A2 | 1,6W |
Casing Material | Polyamid PA non-reinforced |
Operating Voltage Ub | 24V DC (±10%) |
Rated surge voltage/ insulation | 4 kV |
Rated insulation voltage | 13/14, 47/48 - 250V AC 24, 34 - 30V AC |
Terminals | Screw terminals |
Conductor cross-section | 0,25 - 1,5 mm^2 |
Conductor cross-section AWG | AWG 24…16 |
Conductor type | Flexible with ferrule |
Wire stripping length | 8mm |
Tightening torque min/max | 0,5Nm/0,6Nm |
Input Data
Voltage outputs | S11, S22 |
Voltage | 15V DC ± 0.5V |
Outputs
Voltage outputs | S11, S22 |
Voltage | 15V DC ± 0.5V |
Contact outputs | 13/14, 47/48 | 24,34 |
Contact Material | AgNi | - |
Minimum switching current | 10mA | 3mA |
Maximum switching current *Limitation due to design | 6A* 1A | 0,5mA |
Breaking capacity according to IEC60947-5-1 | DC13: 2A/24V DC13 bei 0,1 Hz: 4A/24V AC15: 3A/250V | - |
Mechanical service life | ≥ 10^7 Switch cycles | ≥ 5 x 10^7 Switch cycles |
Contact fuse protection | 5 A gL/gG | 5 A gL/gG |
Response/relapse time typical | 10 ms / 6 ms | 10 ms / 6 ms |
Environmental Data
Operating temperature | -10 °C to +60 °C |
Storage temperature | -40 °C to +85 °C |
Height | < 2000m above Sea Level |
Shock resistance | 15g, all 3 axes |
Block Diagram
Safety-relevant Parameters according to DIN ISO 13849-1
Stop Category according to IEC 60204 | 1 |
Category according to DIN ISO 13849 | 3 |
Performance Level | d |
MTTFd [a] | 98 |
PFHd | 4,3E-08 |
Service Life | 240 months |
Contact Service Life
DNSR 2R: Time Delay Relay Manual
DNSR 2R2: Time Delay Relay Manual
DNSR 2R: Emergency Stop Relay Manual
DNSR 2R: Time Relay – EC declaration of conformity
DNSR 2R2: Time Relay – EC declaration of conformity
DNSR 2R: Time Relay - EC declaration of conformity
Compatibility
- Energy separation of drives
- Unlocking protection
- Can be used in safety circuits according to VDE0113, part 1 with maximum category 3 / PLd according to ISO 13849-1
Branchen
- Woodworking
- Metalworks
- Construction
- Spindles
- Centrifuges
- and many more...
Your advantages summarised.
2 control circuits with one single-channel and one dual-channel contact each.
2 terminals for time setting release, provided that the two-channel contacts are adjustable via potentiometer.
Choice of instantaneous, off-delayed or on-delayed contacts.
Individual time settings are parameterised ex works according to customer specifications. Optionally, the delay times of the safe contacts can be set via a potentiometer.
All contacts are designed as NO. The single-channel contacts can be electrically designed as NC by re-parameterisation.
The connection panel is attached to the side of the unit.
The pluggable terminals are interchangeable.
Inputs and outputs are checked for plausibility.